Aprilaire E070 Installation Manual: A Comprehensive Plan
This manual details the installation of the Aprilaire E070 whole-house humidifier, covering everything from initial setup to troubleshooting, ensuring optimal performance and indoor air quality.

The Aprilaire E070 is a high-capacity, whole-house humidifier designed to add essential moisture to your home’s air during dry heating seasons. This unit effectively combats the discomforts of dry air, such as static electricity, cracked skin, and irritated sinuses, promoting a healthier and more comfortable living environment.
This installation manual provides a step-by-step guide for homeowners and HVAC professionals to properly install and configure the Aprilaire E070. It covers crucial aspects, including safety precautions, necessary tools, system compatibility checks, and detailed instructions for water supply connection, mounting, and electrical wiring.
Proper installation is paramount for optimal performance and longevity of the unit. Following these guidelines will ensure efficient operation, minimize potential issues, and maximize the benefits of a properly humidified home. Remember to consult local codes and regulations during the installation process.
Understanding the Aprilaire E070 Whole-House Humidifier
The Aprilaire E070 operates on a simple yet effective principle: water evaporation. Dry air from your furnace is drawn across a wetted evaporator pad, absorbing moisture before being distributed throughout your home via the ductwork. This process increases the humidity level, alleviating dryness and improving indoor air quality.
Key components include the humidifier cabinet, evaporator pad, water panel, solenoid valve (controlling water flow), and a control panel for adjusting humidity settings. The E070 is designed for compatibility with most forced-air heating systems, but verifying system requirements is crucial before installation.
Understanding how these components interact is vital for successful installation and troubleshooting. The unit’s capacity is substantial, making it suitable for larger homes. Regular maintenance, including pad replacement, ensures continued efficient and healthy operation. Proper airflow is essential for optimal performance.
Safety Precautions Before Installation
Prior to commencing installation, disconnect power to your furnace at the breaker box. This is paramount to prevent electrical shock. Water and electricity are a dangerous combination, so ensure the area is dry. Wear appropriate safety glasses to protect your eyes from debris during drilling and cutting.
Exercise caution when working with plumbing; ensure the water supply is shut off before making any connections. Be mindful of potential lead in older plumbing systems and take necessary precautions. If saddle valves are considered (though not recommended), understand the risks of leaks and potential water damage.
Always consult local building codes and regulations regarding humidifier installation and plumbing connections. If you are uncomfortable with any aspect of the installation, consult a qualified HVAC professional. Proper grounding of electrical components is essential for safe operation.

Tools and Materials Required
For a successful Aprilaire E070 installation, gather these essential tools: a Phillips head screwdriver, a flathead screwdriver, adjustable wrench, pipe cutter (for copper or PEX), drill with various sized bits, level, measuring tape, and a hacksaw. A voltage tester is crucial for confirming power is off.
Materials needed include: the Aprilaire E070 humidifier unit, appropriate water supply line (copper, PEX, or flexible tubing), drain tubing, bypass ducting (if required), wire connectors, electrical tape, Teflon tape for plumbing connections, and mounting screws.
Depending on your existing setup, you might also require a saddle valve (though discouraged), a drain saddle, and potentially additional ductwork or fittings. Having a bucket and towels handy is advisable for managing minor water spills during connections.

Preparing for Installation: System Compatibility
Before beginning, verify your furnace and ductwork are compatible with the Aprilaire E070. The humidifier requires a return air duct with sufficient space for installation and bypass airflow. Confirm your furnace has a compatible control board or that you’ll utilize a separate humidistat.
Assess your water supply. A dedicated cold water line is preferred, ensuring adequate pressure and flow rate. Avoid using hot water lines. Check for existing shut-off valves for easy maintenance.
Evaluate your drain system. A nearby floor drain or standpipe is necessary for condensate disposal. Ensure the drain can handle the anticipated water volume. Improper compatibility can lead to system inefficiencies or damage, so careful assessment is vital for a smooth installation.

Locating the Ideal Installation Spot
Choose a location near your furnace’s return air duct, allowing for easy connection and minimal ductwork modification. The area should be accessible for future maintenance, including filter and evaporator pad replacements. Ensure sufficient clearance around the unit for comfortable working space.
Avoid areas prone to freezing temperatures, as this can damage the water supply line and humidifier components. A dry, protected location is crucial. Consider proximity to a water supply and drain for simplified connections.
The installation spot must support the humidifier’s weight when fully operational, including water. Proper structural support is essential. Prioritize a location that minimizes airflow restrictions and maximizes humidification efficiency.
Water Supply Connection
Connecting the Aprilaire E070 to a reliable water source is critical. A dedicated cold water line is highly recommended for consistent performance and to avoid potential issues with hot water systems. Ensure the water pressure falls within the manufacturer’s specified range – typically between 20 and 80 PSI.
Use a ¼-inch compression fitting to connect the water supply line to the humidifier’s inlet valve. Apply Teflon tape to the threads for a watertight seal. Inspect the connection thoroughly for leaks after initial startup.
Proper water filtration is advisable to prevent mineral buildup within the humidifier, extending its lifespan and maintaining optimal efficiency. Consider installing a sediment filter upstream of the unit.
Connecting to a Cold Water Line
Establishing a direct connection to a cold water line provides the most reliable water supply for your Aprilaire E070. Locate a suitable cold water pipe, ideally within a few feet of the humidifier, minimizing the length of the supply tubing.
Carefully drill a hole into the cold water pipe using a sharp bit designed for plumbing applications. Install a saddle fitting with a ¼-inch compression outlet. Ensure the saddle fitting is securely clamped to the pipe, creating a watertight seal.
Connect the ¼-inch tubing from the humidifier to the compression outlet on the saddle fitting. Double-check all connections for tightness and potential leaks before proceeding. A properly installed cold water line ensures consistent water flow and optimal humidifier operation.
Saddle Valve Installation (Not Recommended)
While saddle valves offer a seemingly simpler installation method, they are strongly discouraged for use with the Aprilaire E070 humidifier. These valves clamp onto the pipe and pierce the water line, creating a potential for leaks and reduced water flow.
The piercing action can damage the pipe over time, leading to corrosion and eventual failure. Furthermore, saddle valves are prone to clogging due to mineral buildup and debris, hindering the humidifier’s performance.
If a direct connection to the cold water line is impractical, consider professionally installing a dedicated supply line with a shut-off valve. This provides a more reliable and long-lasting solution, ensuring consistent water supply and preventing potential water damage. Prioritize a secure, direct connection for optimal operation.
Humidifier Mounting and Securing
Proper mounting is crucial for stable operation and preventing vibrations during the Aprilaire E070’s function. Select a sturdy, level surface capable of supporting the humidifier’s weight when fully operational, including a filled water panel.
Utilize the provided mounting bracket and screws to securely attach the unit to a joist or wall stud. Ensure the bracket is flush against the mounting surface before tightening the screws. Avoid mounting directly to drywall without proper anchoring.
Verify the humidifier is level after installation using a spirit level. Adjust as needed to eliminate any wobble. Securely fasten all connections and components to minimize noise and ensure long-term stability. A firm, level mount is essential for optimal performance and longevity.
Evaporator Pad Installation
The evaporator pad is the heart of the Aprilaire E070’s humidification process, responsible for absorbing water and facilitating evaporation. Carefully remove the new evaporator pad from its packaging, avoiding any damage to the delicate fibers.
Align the pad with the designated slots within the humidifier housing. Ensure it fits snugly and completely, without any gaps or overlaps. Proper alignment maximizes airflow and evaporation efficiency.
Gently press the pad into place, ensuring it’s fully seated. Avoid forcing it, as this could tear the material. A correctly installed pad will offer minimal resistance to airflow and provide optimal humidification. Regularly inspect and replace the pad as recommended to maintain peak performance and air quality.

Water Panel Assembly
The water panel assembly distributes water evenly across the evaporator pad, crucial for efficient humidification. Begin by carefully inspecting all components – the water distribution tube, the water panel itself, and any connecting clips or fasteners.
Position the distribution tube along the top of the evaporator pad area, ensuring the water outlets are correctly aligned to deliver water across the entire pad surface. Secure the tube using the provided clips, guaranteeing a stable and leak-proof connection.
Next, place the water panel onto the distribution tube, confirming a snug fit. Proper alignment prevents uneven water distribution and maximizes the pad’s absorption capacity. Regularly check for leaks and ensure all connections remain secure for optimal performance and to avoid water damage.
Drain Line Installation
Proper drain line installation is vital to prevent water damage and maintain humidifier functionality. Begin by selecting a suitable drain location – a floor drain, standpipe, or laundry tub – ensuring it can accommodate the continuous water flow from the humidifier.
Connect the provided drain hose to the humidifier’s drain outlet, securing it with a hose clamp to prevent leaks. Route the hose towards the chosen drain, avoiding sharp bends or kinks that could restrict water flow. Ensure the hose is adequately supported throughout its length.
Avoid direct connection to a sewer line, as this can cause unpleasant odors. Regularly inspect the drain line for clogs or obstructions, and maintain a consistent downward slope to facilitate efficient drainage. A properly installed drain line ensures long-term, trouble-free operation.
Connecting to a Drain
Establishing a secure connection to a suitable drain is crucial for the Aprilaire E070’s operation. Locate a nearby floor drain, standpipe, or laundry tub capable of handling the continuous water discharge. Avoid connecting directly to the sewer line to prevent potential odor issues within your home environment.
Utilize the provided drain hose and secure it firmly to the humidifier’s drain outlet using a hose clamp. This prevents accidental disconnections and potential water leaks. Carefully route the hose towards the chosen drain, ensuring a smooth path free from sharp bends or constrictions.
Double-check the connection at the drain end, ensuring a snug fit to prevent backflow or splashing. Regularly inspect this connection for any signs of wear or loosening, maintaining a dry and functional system.
Ensuring Proper Drainage Slope
Maintaining a consistent downward slope in the drain line is paramount for effective water removal from the Aprilaire E070 humidifier. Without adequate slope, water can accumulate, leading to potential mold growth, system inefficiencies, and even water damage within your home.
A minimum slope of ¼ inch per foot is recommended throughout the entire length of the drain line. This gentle decline allows gravity to efficiently carry water away from the humidifier and towards the designated drain point. Avoid any sections where the drain line rises or remains level.
Secure the drain line properly to prevent sagging or dips that could create pockets for water to collect; Use appropriate supports and fasteners to maintain the correct slope consistently. Regular inspection of the drain line is vital to confirm continued proper function.

Furnace Integration and Bypass Ducting
Proper integration with your furnace and the implementation of bypass ducting are crucial for the Aprilaire E070’s optimal performance and to prevent negative pressure within your HVAC system. The humidifier needs to be seamlessly incorporated into the airflow path to effectively distribute moisture throughout your home.
Bypass ducting diverts a portion of the furnace’s warm air over the evaporator pad, providing the energy needed for evaporation. This warmed, humidified air then rejoins the main airflow, delivering comfortable humidity levels. Correct sizing of the bypass duct is essential; too small restricts airflow, while too large reduces heating efficiency.
Ensure the bypass duct is securely connected to both the furnace and the humidifier housing, using appropriate duct tape and clamps to prevent air leaks. A properly installed bypass duct maintains consistent humidity and protects your furnace from overworking.
Electrical Connections
Establishing secure and correct electrical connections is paramount for the safe and reliable operation of your Aprilaire E070 humidifier. Always disconnect power to the furnace at the breaker box before commencing any electrical work. Incorrect wiring can lead to system malfunction, electrical hazards, or even fire.

The E070 typically requires a 24V AC power source, often obtained from the furnace’s control board. Consult the wiring diagram included with your humidifier and furnace to identify the appropriate terminals. Use appropriately sized wire connectors and ensure all connections are tight and insulated.
Grounding the humidifier is essential for safety. Follow local electrical codes and regulations. If you are uncomfortable performing electrical work, it is strongly recommended to hire a qualified HVAC technician to complete this step. Double-check all connections before restoring power.
Control Panel Wiring
Proper control panel wiring is crucial for seamless integration of the Aprilaire E070 with your home’s HVAC system. The control panel manages humidity levels and fan operation, responding to thermostat signals and internal sensors. Refer to the detailed wiring diagram provided with both the humidifier and your existing thermostat.
Typically, wiring involves connecting the control panel to the furnace’s control board for power and signals. This includes connections for the humidistat (humidity sensor), fan activation, and potentially a solenoid valve control. Ensure correct polarity and secure connections using wire nuts or terminal blocks.
Carefully label each wire before disconnecting anything during installation to avoid confusion. If your system includes a remote humidity sensor, follow the specific instructions for its wiring. Incorrect wiring can prevent the humidifier from functioning correctly or damage the control panel.
Initial System Startup and Testing
After completing the installation, a thorough system startup and testing phase is essential to verify proper operation of the Aprilaire E070. Begin by restoring power to the furnace and humidifier control panel. Observe the control panel display for any error codes or unusual behavior, consulting the troubleshooting section if necessary.
Activate the furnace fan and confirm the humidifier’s water panel is receiving water. Check for leaks around all water connections – the supply line, drain line, and within the humidifier itself. Adjust the control panel settings to initiate a humidification cycle and monitor the humidity levels in your home.
Verify the bypass duct is functioning correctly, ensuring adequate airflow through the humidifier. Use a humidity meter to confirm the humidifier is effectively increasing indoor humidity. Document these initial readings for future reference and comparison.
Aprilaire E070 Settings and Adjustments
The Aprilaire E070 control panel offers customizable settings to optimize performance based on your home’s specific needs and climate. Familiarize yourself with the humidity control options, allowing you to select a desired humidity level, typically between 30% and 50%. Explore the automatic humidity control feature, which adjusts output based on outdoor temperature.
Adjust the fan speed settings to match your furnace’s capabilities and ductwork configuration. Experiment with different settings to find the optimal balance between humidification and airflow. Utilize the manual override function for temporary adjustments, such as during periods of extreme weather.
Regularly review and fine-tune these settings to maintain consistent and comfortable humidity levels throughout the year, maximizing energy efficiency and indoor air quality. Refer to the control panel’s display for real-time humidity readings and system status.
Troubleshooting Common Installation Issues

During Aprilaire E070 installation, several issues may arise. Water leaks are common; immediately check all connections – the water supply line, drain line, and humidifier body – ensuring tight seals. If the unit isn’t producing humidity, verify the water supply valve is fully open and the evaporator pad is correctly installed and saturated.
Electrical problems can occur; confirm proper wiring connections at the furnace control board and the humidifier itself. A malfunctioning solenoid valve might prevent water flow; test its operation with a multimeter. If the bypass duct isn’t properly configured, airflow issues can arise, reducing humidification effectiveness.
Consult the wiring diagram and double-check all connections. If problems persist, refer to the Aprilaire support resources or a qualified HVAC technician for assistance.
Maintenance and Filter Replacement
Regular maintenance ensures optimal Aprilaire E070 performance and longevity. The evaporator pad requires annual replacement, typically before the heating season, to maintain efficient humidification. Inspect the pad for mineral buildup or clogging, which reduces airflow and humidity output.
The water panel should also be cleaned annually to remove scale and debris, preventing restricted water flow. Periodically check the drain line for obstructions, flushing it with water to ensure proper drainage and prevent water damage. Inspect the solenoid valve for leaks or malfunctions.
Annual inspection of all connections is crucial. Following these simple maintenance steps will extend the life of your humidifier and maintain healthy indoor air quality. Refer to the Aprilaire website for specific replacement part numbers and detailed instructions.
Warranty Information and Support Resources
Aprilaire products are backed by a comprehensive warranty, protecting against defects in materials and workmanship. The E070 humidifier typically carries a five-year limited warranty on the humidifier itself, and a one-year warranty on parts. Registration of your product is essential to activate the full warranty coverage; visit the Aprilaire website to register.
For technical support, troubleshooting assistance, or warranty claims, Aprilaire offers multiple resources. Their website (aprilaire.com) provides a detailed FAQ section, downloadable manuals, and instructional videos. You can also contact Aprilaire’s customer support team via phone or email.

Authorized Aprilaire dealers are also available to provide professional installation, maintenance, and repair services. Keep your proof of purchase for warranty claims and service requests. Detailed warranty terms and conditions are available in the product documentation.